Pump-Mounted Water Heaters
BWCV - Copper Brute II
Indoor/Outdoor Sizes 199,900 - 1,999,000 BTU/Hr.
84% Thermal Efficiency
The unit will be designed and constructed in accordance with the ASME Boiler and Pressure Vessel Code Section IV requirements for 160 psi working pressure.
The units will bear the ASME "H" stamp and be registered by the National Board.
5-Year Limited Heat Exchanger Warranty / 1-Year Limited Warranty on Component Parts.
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties.
See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171;
(B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534;
7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105;
2,409,271. ©2008, Bradford White Corporation. All rights reserved. Printed in U.S.A.
720-B 0908
Copper-Brute II (200-400)
Water Heater Specifications
1 2 3
B W C
4
V
5 6 7 8
9
10
A
11
12
13
1
14
15
16
SERIES
USAGE
V
SIZE
FUEL
ALTITUDE LOCATION
A
FIRING
MODE
REVISION
HEAT
OPTIONS
CODE
PUMP
EXCHANGER
OPTIONS
0
0
0
2
3
4
0
0
0
0
0
0
N
P
C=On-Off (std.)
K=Two-Stage
B (std.)
P
L (std.)
N (std.)
S
C=Convertible
Model Character Designation
(1-3) Model Series Designation
B W C = Copper Brute II
(12) Firing Mode
C = On-Off (standard on all models)
K = Two-stage (optional on all models)
(4) Usage
V = Volume Water
(13) Revision
1 = First Revision of Design
(5-8) Size
(14) Heat Exchanger
B = Glass-lined cast iron headers / copper / bronze trim
P = Glass-lined cast iron headers / cu-nickel / bronze trim
0 2 0 0 = 199,900 BTU/Hr. input
0 3 0 0 = 299,900 BTU/Hr. input
0 4 0 0 = 399,900 BTU/Hr. input
(15) Option Code
L = Low Temp. Control
(9) Fuel
N = Natural Gas
P = Propane
(16) Pump Options
(10) Altitude
A = 1-10,000 feet
N = Pump mounted water heater, normal water pump
S = Pump mounted water heater, soft water pump
(11) Location
C= Convertible
Copper-Brute II Models
Gas2 Water2
Conn. Conn.
Shipping
Weight
(lbs.) (kg)
WATER TEMPERATURE RISE IN DEGREES
Model
Input1
BTU/Hr.
Output1
BTU/Hr.
90°F
GPH
50°C
100°F
56°C
140°F
78°C
Numbers
LPH
GPH
LPH
GPH
LPH inches inches
3
BWCV0200
BWCV0300
BWCV0400
199,900
299,900
399,900
169,900
254,900
339,900
227
340
453
858
1285
1712
204
306
408
771
1157
1542
146
219
291
552
828
⁄
4
11⁄
11⁄
11⁄
2
290 132
320 145
350 159
3
⁄
4
2
3
1100
⁄
4
2
1. Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.
2. Dimensions are nominal.
Note: GPH = gallons per hour, LPH = liters per hour.
Water Flow Data
Firing Rates
Model Numbers Firing Stage
HARD WATER
NORMAL WATER
SOFT WATER
BWCV0200
BWCV0300
BWCV0400
On/Off*
On/Off*
On/Off*
Model
Numbers
Flow
GPM
Flow
LPM
Flow
GPM
Flow
LPM
Flow
GPM
Flow
LPM
87
BWCV0200
BWCV0300
BWCV0400
45
45
45
170
170
170
35
35
35
133
133
133
23
23
23
* Two-stage available as an
option.
87
87
Note: GPM= gallons per minute, LPM=liters per minute
Copper-Brute II (500-2000)
Water Heater Dimensions
Dimensions are shown in inches.
W*
V*
193/4
B
F
C
G
V*
W*
W*
V*
411/2
351/3
133/4
133/4
183/4
2
122/5
10
A
73/4
H
291/3
V*
W*
D
E
C
B
DIMENSIONS
A
B
C
D
E
F
G
H
W*
V*
Ct. Line
Air
Ct. Line
Vent
Ct. Line
Ct. Line
Ct. Line
Ct. Line
Air Connect Vent Connect
Length
Plus
Pump
Horiz.
Vent
Max.
Pipe
No.
of
Vent Connect Air Connect
Connect
to Floor
inch cm inch cm
Connect
to Floor
to Back
of Unit
to Back
of Unit
inch cm
Air
Connect
Vent
Connect
inch cm inch cm
Model
Numbers
Length
inch cm
to Side
to Side
inch cm
Pipe
Length Elbows
inch cm
inch cm
inch cm inch cm
BWCV0500 331
BWCV0750 451
BWCV1000 571
/
/
/
2
2
2
85 153
116 213
146 283
/
/
/
4
4
4
40
55
73
86 101
101 101
113 101
126 101
53
53
53
/
/
/
4
4
4
15 293
15 293
15 293
26 303
26 303
26 303
26 303
/4
/4
/4
/4
/4
/4
/4
76 323
76 323
76 323
78 291
78 291
78 291
78 291
/
/
/
/
/
/
/
4
4
4
2
2
2
2
83
83
83
75
75
75
75
73
73
73
83
83
83
83
/4
/4
/4
/4
/4
/4
/4
20
20
20
28
28
28
28
83
83
/
4
22
22
18
22
22
22
22
46 117
58 147
70 178
80 203
91 231
101 256
6
6
8
8
8
8
15
15
20
20
20
20
8
20
6
8
8
8
8
8
15
20
20
20
20
20
50ft.
50ft.
50ft.
50ft.
50ft.
50ft.
50ft.
3
3
3
3
3
3
3
/4
10 25
10 25
12 30
12 30
14 36
14 36
7
BWCV1250
BWCV1500 781
BWCV1750
89 226 441
BWCV2000 991 253 493
68 172
34
/
/
/
/
8
83
83
83
83
/4
/4
/4
/4
/2
199 393
/
/
/
4
2
4
8
8
8
/2
112 284 12 20
12 30
* Air and vent connections may be on top or back of unit and are field convertible.
Copper-Brute II (500-2000)
Water Heater Specifications
1 2 3
B W C
4
V
5 6 7 8
9
10
A
11
12
13
2
14
15
16
SERIES
USAGE
V
SIZE
FUEL
ALTITUDE LOCATION
A
FIRING
MODE
REVISION
HEAT
OPTIONS
CODE
PUMP
EXCHANGER
OPTIONS
0
0
1
1
1
1
2
5
7
0
2
5
7
0
0
5
0
5
0
5
0
0
0
0
0
0
0
0
N
P
K=Two-Stage
N=Three-Stage
L=Four-Stage
B (std.)
X (std.)
J
L
N (std.)
S
H
K
P
S
C=Convertible
Model Character Designation
(1-3) Model Series Designation
(11) Location
(15) Option Code
C=Convertible
X = Standard
B W C = Copper Brute II
J = CSD-1, FM, IRI, IL
L = LDS (consult factory)
(12) Firing Mode
(4) Usage
V = Volume Water
K = Two-stage (500 & 750)
N = Three-stage (1000)
L = Four-stage
(16) Pump Options
N = Pump mounted water heater,
normal water pump
S = Pump mounted water heater,
soft water pump
H = Pump mounted water heater,
hard water pump
(5-8) Size
0 5 0 0 = 500,000 BTU/Hr. input
0 7 5 0 = 750,000 BTU/Hr. input
1 0 0 0 = 999,000 BTU/Hr. input
1 2 5 0 = 1,250,000 BTU/Hr. input
1 5 0 0 = 1,500,000 BTU/Hr. input
1 7 5 0 = 1,750,000 BTU/Hr. input
2 0 0 0 = 1,999,000 BTU/Hr. input
(1250, 1500, 1750 & 2000)
(13) Revision
2 = First Revision of Design
(14) Heat Exchanger
B = Glass-lined cast iron headers /
copper tubes/ bronze trim
K = Bronze headers / copper tubes/
bronze trim
P = Glass-lined cast iron headers /
cu-nickel / bronze trim
(9) Fuel
N = Natural Gas
P = Propane
(10) Altitude
A = 0-10,000 feet
S = Bronze headers / cu-nickel /
bronze trim
Copper-Brute II Models
Gas2 Water2
Conn. Conn.
Shipping
Weight
(lbs.) (kg)
WATER TEMPERATURE RISE IN DEGREES
Model
Input1
BTU/Hr.
Output1
BTU/Hr.
90°F
GPH
50°C
100°F
56°C
140°F
78°C
Numbers
LPH
GPH
LPH
GPH
LPH inches inches
BWCV0500
BWCV0750
BWCV1000
BWCV1250
BWCV1500
BWCV1750
BWCV2000
500,000
750,000
999,000
425,000
638,000
849,000
567
850
2143
3214
4281
5357
6429
7500
8567
510
765
1929
2893
3853
4821
5786
6750
7710
364
547
1378
2066
2752
3444
4133
4821
5507
11⁄
11⁄
11⁄
4
2
480 218
560 254
670 304
730 331
815 370
880 400
1010 459
4
2
1133
1417
1701
1984
2266
1019
1276
1531
1786
2040
728
2
21⁄
21⁄
21⁄
21⁄
21⁄
2
1,250,000 1,063,000
1,500,000 1,275,000
1,750,000 1,488,000
1,999,000 1,699,000
911
2
2
2
2
2
1093
1276
1457
2
2
2
1. Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.
2. Dimensions are nominal.
Note: GPH = gallons per hour, LPH = liters per hour.
Firing Rates
Water Flow Data
Model Numbers
BWCV0500
BWCV0750
BWCV1000
BWCV1250
BWCV1500
BWCV1750
BWCV2000
Firing Stage
2-Stage
2-Stage
3-Stage
4-Stage
4-Stage
4-Stage
4-Stage
HARD WATER
NORMAL WATER
SOFT WATER
Model
Flow
GPM
Flow
LPM
Flow
GPM
Flow
LPM
Flow
GPM
Flow
Numbers
LPM
170
170
170
257
257
257
424
BWCV0500
BWCV0750
BWCV1000
BWCV1250
BWCV1500
BWCV1750
BWCV2000
90
90
341
341
341
341
341
341
424
68
68
68
68
68
68
257
257
257
257
257
257
424
45
45
90
45
90
68
90
68
90
68
112
112
112
Note: GPM= gallons per minute, LPM=liters per minute
Standard Features
I Thermal efficiency up to 85%
I Manual “A” gas valve
I Electronic PID staging control with LCD
and touchpad
I ASME 160 psi working pressure heat
exchanger
I ASME "H" stamp, designed and certified
for potable water use
I Flanged bronze water connections
I Glass-lined headers
I External header gaskets
I 125 psi (861 kPa) ASME rated pressure
relief valve
I Flow switch, mounted and wired
I Temperature/pressure gauge
I Pump, mounted and wired
I Multiple operating gas valve/pressure
regulators
I Washable intake air filter
I Multiple, removable burner trays
I Stainless steel burners
I Built-in draft fan for Category I or III vent
systems
I Air pressure switch
I Burner site glass
I PC board for electrical connections
I External controller connections with
selector switch
I Hot surface ignition
I On/Off toggle switch
I Pump time delay
I Diagnostic lights
I Less than 10 ppm NOx (500-2000 only)
I Less than 30 ppm NOx (200-400 only)
I All models can be converted to either
indoor use or outdoor use. For outdoor
use, you must order exhaust vent and air
intake vent (consult factory for part
numbers)
I 24V control system
I 115/24VAC transformer
I Ignitor access panels
I Energy Management Monitor (EM2)
pump time delay
I Manual reset high limit
I Automatic reset high limit (500-2000 only)
Optional Equipment
I Copper-nickel heat exchanger
I CSD-1 Package includes:
I LDS Package includes:
I Normally open vent valve (500-2000 only,
Size 500-2000:
Single Try Ignition, High and Low Gas
Pressure Switches, and Gas Regulator.
Size 500-1000:
Safety Valve with Gas Regulator, High Gas
Pressure Switch and Leak Test Valve.
see IRI Package)
I Low water cutoff
I Motorized gas safety valve
Excludes Low Water Cutoff.
I IRI Package, added to the CSD-1 package
includes:
Size 1250-2000:
(500-2000, see LDS Package)
Solenoid Safety Valve, Motorized Valve
with Proof of Closure, Leak Test Valve,
High and Low Gas Pressure Switches.
I Double stack stand (500-2000 only)
I Reverse Heat Exchanger - switches the
inlet and outlet to left side and pump to the
right side
I Indoor Venting Accessories (required for
sidewall venting)
Size 500-2000:
Single Try Ignition, High and Low Gas
Pressure Switches with Manual reset,
Normally Open Vent Valve, Safety Valve
with Gas Regulator and Leak Test Valve.
Excludes Low Water Cutoff
Clearances
Motor Electrical Data
APPLIANCE
SURFACE
REQUIRED CLEARANCE FROM
SUGGESTED SERVICE
ACCESS CLEARANCES
WATER CATEGORY
COMBUSTIBLE MATERIAL
Power (HP)
Current (Amps)
Soft Normal Hard
inch
1
cm
2.5
2.5
2.5
2.5
2.5
inch
24
24
12
12
36
cm
61
61
30
30
91
Model Numbers
BWCV0200
BWCV0300
BWCV0400
BWCV0500
BWCV0750
BWCV1000
BWCV1250
BWCV1500
BWCV1750
BWCV2000
Soft
Normal Hard
Left Side
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
⁄3
⁄
3
⁄
4
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
7.2
9.8
2.8
2.8
2.8
2.8
2.8
5.2
5.2
7.2
7.2
9.8
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
9.8
Right Side
Top
1
1
1
1
1
1
1
1
3
⁄
3
⁄3
⁄4
1
⁄3
⁄3
⁄4
Back*
Front
1
⁄3
⁄3
⁄4
1
⁄3
⁄3
⁄4
Per venting supplier’s instructions
Vent
⁄3
⁄2
⁄4
⁄3
⁄2
⁄4
*When vent and/or air is connected to the back, 36" (91cm) is suggested.
⁄3
⁄4
⁄4
⁄4
⁄4
⁄4
1
1
1
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
G
G
G
G
Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089